Bracker Raku Kiln Firing Tips and Troubleshooting
The most common question we get relates to problems getting the kiln up to temperature. This is usually caused by one of two things:
1. The burner is too close to (or inside) of the kiln itself. This impedes the combustion, no combustion = no fire and no fire = no heat. To resolve this, pull the burner out and allow around 6" of fresh air between the edge of the torch and the inflow on the kiln
2. Burner and Tank mismatch - We originally only offered the kit with a 500k burner. At that time, 100# propane tanks were readily available and could be rented rather inexpensively...However, as time passed, people began to attempt to fire using a 20# tank like the ones on a gas grill. These firings were rarely succesful. This is because the burner was too big for the tank. Basically, the burner is trying to pull gas out faster than the tank can supply it. The burners themselves are designed to draw propane out of the tank as a gas, but LP in the tank is a liquid. That is why there is empty headspace in the tank. The LP liquid evaporates into this headspace and that gas is what is drawn through the burner. If your burner is too big, your tank cannot convert the liquid to gas quickly enough to keep up with the burner and you never achieve the proper gas pressure at the burner head. You burn a lot of gas, but the actual BTUs being produced are nowhere near enough to successfully fire the kin. The kiln will get hot, but it will stall out (usually before you even hit red heat) as the flame is not as hot as it needs to be for the temperature to climb.
You have 2 options to fix the issue, and both will work for this kiln.
1- Replace your burner with a 100k BTU burner. When we ran our tests on the kiln with the 100k burner, we were able to get 2-3 firings out of a 20# tank before there was insufficient liquid remaining in the tank to evaporate and create the proper tank pressure. The quantity of firings per tank is also dependent on load size, air temperature and barometric pressure on firing day.
2 - Fire using a LARGER tank. In our testing, the 500k burner needs a tank NO SMALLER than 40# to achieve the proper gas pressure on the larger burner.